Framegrabber für Sony XCL-5005/CR
Kriterien für kompatible Framegrabber
Framegrabber |
Cable |
Camera |
Valid Combination |
| Conventional |
Conventional |
Conventional |
Yes, operates normally |
| PoCL |
Only if the camera has an auxiliary power connector |
| PoCL |
Conventional |
Yes, operates normally |
| PoCL |
Only if the camera has an auxiliary power connector |
| PoCL |
Conventional |
Conventional |
Only if the framegrabber supports SafePower |
| PoCL |
Only if the camera has an auxiliary power connector |
| PoCL |
Conventional |
Only if the framegrabber supports SafePower |
| PoCL |
Yes, frame grabber powers camera |
Folgende Framegrabbermodelle eignen sich für den Einsatz
mit der XCL-5005/CR
|
CL config |
PC interface |
Pixel clock |
PoCL support |
Validated interface |
COGNEX MVS-8600e |
Dual Base or Medium |
PCIe x4 |
85 MHz |
No |
should work |
Dalsa Coreco X64 Xcelera-CL PX4 Dual |
Dual Base or Medium |
PCIe x4 |
85 MHz |
No |
Yes |
Euresys GrabLink Express |
Base |
PCIe x1 |
85 MHz |
Yes - SafePower |
Yes |
GigaLinx Connect SA-CLB |
Base |
GigE Vision |
85 MHz |
No |
Yes |
Leutron PicPort-Exp-CL |
Base |
PCIe x1 |
85 MHz |
Yes - SafePower |
should work |
Matrix Vision mvHyperion-Cle |
Dual Base or Medium |
PCIe x1 |
85 MHz |
No |
should work |
Matrox Imaging Solios eCL/XCL-B |
Base |
PCIe x1 |
85 MHz |
Should be |
Yes |
Matrox Imaging Solios eCL/XCL |
Dual Base or Medium |
PCIe x4 |
85 MHz |
No |
Yes |
Pleora PT1000-CL |
Base |
GigE Vision |
66 MHz |
No |
Yes |
NI NI-IMAQ PCIe-1427 |
Base |
PCIe x1 |
80 MHz |
No |
should work |
|